Cyber Power Smart App UPS Systems OLS6000E

11,682,000.00 MMK 11682000.0 MMK 11,682,000.00 MMK

11,682,000.00 MMK

  • Phase
  • Form Factor
  • Energy Saving Technology
  • UPS Topology
  • Features
  • Parallel Expansion
  • Nominal Input Voltage ( Vac )
  • Input Voltage Range
  • Adjustable Voltage Range
  • Input Frequency
  • Input Frequency Detection
  • Rated Input Current ( A )
  • Input Power Factor
  • Input Connector Type
  • Capacity
  • On Battery Waveform
  • On Battery Voltage(s)
  • Output Voltage/ Frequency Setting
  • On Battery Frequency
  • ECO Mode Voltage Tolerance
  • overload protection
  • Crest Factor
  • Harmonic Distortion
  • Internal Bypass
  • Outlet(s)
  • Outlet Type:
  • Typical Transfer Time ( ms )
  • Runtime
  • Typical Recharge Time
  • maximum charge current
  • Battery Type
  • Compatible Extended Battery Module
  • Max. EBM Quantity 
  • Surge Suppression ( Joules )
  • LCD Information Display
  • LCD Setting & Control
  • LED Indicator
  • Audible Alarms
  • Management Cable
  • Power Management Software
  • Enclosure Construction
  • Color
  • Warranty

This combination does not exist.

Phase: Single Phase
Form Factor: Tower
Energy Saving Technology: Online ECO Mode Efficiency > 96%
UPS Topology: Online Double Conversion
Features: Active PFC Compatibility, Generator Compatibility, Maintenance Bypass, Start On Battery, Smart Battery Management (SBM), EMI/RFI Filtration, LCD Panel, Emergency Power Off (EPO) Port
Parallel Expansion: 4 (Max. Units)
Nominal Input Voltage ( Vac ) : 230 Vac
Input Voltage Range: 110 ~ 276(Vac)
Adjustable Voltage Range: 0~80% Load for 110 ~ 276 Vac/ 0~100% Load for 176 ~ 276 Vac
Input Frequency: 50 ± 5/ 60 ± 6(Hz)
Input Frequency Detection: Auto-sensing
Rated Input Current ( A ) : 27.3
Input Power Factor: 0.99
Input Connector Type: Hardwire Terminal Block
Capacity: 6000 VA/5400 Watts
On Battery Waveform: Pure Sine Wave
On Battery Voltage(s): 208 ± 1%/ 220 ± 1%/ 230 ± 1%/ 240 ± 1%(Vac)
Output Voltage/ Frequency Setting: Configurable/Configurable
On Battery Frequency: 50 ± 0.1%/ 60 ± 0.1%(Hz)
ECO Mode Voltage Tolerance: ± 10 %
overload protection: Internal Current Limiting, Circuit Breaker, Fuse, 110~120% Load for 1 min, >120% Load Immediately(Line Mode),110~120% Load for 10 sec, >120% Load Immediately(Battery Mode),>130% Load Immediately(Bypass Mode)
Crest Factor: 0.125694
Harmonic Distortion: THD<2%(Linear Load),THD<5%(Non-linear Load)
Internal Bypass: Automatic Bypass, Manual Bypass
Outlet(s) : Total : 1
Outlet Type:: Hardwire Terminal Block x 1
Typical Transfer Time ( ms ): 0
Runtime: 18 min(Half Load),7 min(Full Load)
Typical Recharge Time: 7 Hours
maximum charge current: 1 A
Battery Type: Sealed Lead-acid
Compatible Extended Battery Module: BPSE240V47A
Max. EBM Quantity : 15 pcs
Surge Suppression ( Joules ): 445
LCD Information Display : : Operation Type, Power Status, Battery Status, Load Status, Fault & Warning, Other Information, Event & Log
LCD Setting & Control : Mode Setting, Alarm Setting, Input & Output, Battery Setting, Fault & Warning, Communication, Event & Log, Security Setting
LED Indicator: Line Mode, Battery Mode, Bypass Mode, UPS Fault
Audible Alarms : Battery Mode, Low Battery, Overload, Overcharge, Overheat, UPS Fault, Replace Battery
Management Cable: USB Cable x1(pcs)
Power Management Software: PowerPanel Business (Recommended)
Enclosure Construction: Metal
Color: Black
Warranty: 1 Year Battery , 2 Years Parts , 3 Years Service